Sign In | Join Free | My infospaceinc.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Patient Monitor Parts >

Edan IM70 Patient Monitior 12.1 Inch Display With Touch Screen BOE BA121S01-200

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Edan IM70 Patient Monitior 12.1 Inch Display With Touch Screen BOE BA121S01-200

Brand Name : Edan

Model Number : BOE BA121S01-200

MOQ : 1pcs

Payment Terms : T/T(wire transfer), Western Union, Paypal

Delivery Time : 3-5 working days

Packaging Details : Carton

Product Name : Edan iM70 Patient Monitior 12.1inch Display BOE BA121S01-200

Brand : Edan

Part No : BOE BA121S01-200

Use for : Edan iM70 Patient Monitior

Display screen : 12.1 inch

Display Type : color TFT

Support touch screen or not : yes

Patient monitor size : 328mm(L) × 158mm(W) × 285mm(H)

Patient monitor weight : <5.5kg

MOQ : One

Contact Now

Edan IM70 Patient Monitior 12.1inch Display With Touch Screen BOE BA121S01-200

Edan iM70 Patient Monitior 12.1inch Display BOE BA121S01-200

The iM70 monitor monitors parameters such as ECG (3-lead, 5-lead selectable), Respiration (RESP), Functional arterial oxygen saturation (SpO2), Invasive or noninvasive blood pressure (2/4 channels IBP NIBP), Cardiac Output (CO), Temperature (dual-TEMP), Expired CO2 and Anesthetic gas (AG). The monitor is equipped with alarms that indicate system faults (such as loose or defective electrodes), physiologic parameters that have exceeded the limits set by the operator, or both.

Specification of display

Display screen 12.1 inch
Resolution 800×600
Patient monitor size 328mm(L) × 158mm(W) × 285mm(H)
Patient monitor weight <5.5kg
Type color TFT
Support touch screen or not Yes

WARNING

1. In order for the monitor to work properly, please read the user manual and follow the steps before using the monitor.

2. Before using the equipment, check the equipment, patient cables, electrodes, etc. They should be replaced if they show obvious defects or signs of wear that could affect safety or performance.

3. Medical engineering equipment such as these monitors/monitoring systems should only be used by personnel who have been properly trained in the proper use of such equipment.

4. Explosion hazard: Do not use this device in a flammable environment where anesthetics or other flammable substances may be concentrated.

5. Electric Shock Hazard - To avoid the risk of electric shock, this equipment should only be connected to a protectively grounded power source. Never convert the three-prong connector of the monitor into a two-prong socket.

6. Do not touch the patient, the table or the monitor during defibrillation.

7. The simultaneous use of pacemakers and other devices connected to the patient may present potential safety risks.

8. Magnetic and electric fields can interfere with the normal operation of the device. Therefore, ensure that all external equipment operating near the monitor complies with the relevant EMC requirements. X-ray or MRI machines are potential sources of interference as they may emit higher levels of electromagnetic radiation.

9. Be especially careful when using electrical medical equipment. Many parts of human/machine circuits are conductive, such as patients, connectors, electrodes, transducers. It is very important that these conductive parts do not come into contact with other grounded conductive parts when connected to the isolated patient input of the device. This contact engages patient isolation and cancels the protection provided by the isolated input. In particular, the neutral electrodes and the grounding wires must not touch each other.

10. Carefully route all cables to avoid possible entanglement, strangulation, or electrical interference. For patient-mounted equipment, appropriate precautions must be taken to prevent it from falling onto the patient.

11. The equipment connected to the display must be equipotential.

12. If protective earthing is in doubt, the display may only be powered from the internal power supply.

Edan IM70 Patient Monitior 12.1 Inch Display With Touch Screen BOE BA121S01-200

Thank you so much for your attention .If you're interested in Edan iM70 Patient Monitior 12.1inch Display BOE BA121S01-200 ,feel free to contact us .Thank you .


Product Tags:

Edan IM70 Patient Monitior

      

BA121S01-200 Patient Monitior

      
Quality Edan IM70 Patient Monitior 12.1 Inch Display With Touch Screen BOE BA121S01-200 for sale

Edan IM70 Patient Monitior 12.1 Inch Display With Touch Screen BOE BA121S01-200 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)